| Working voltage: |
12 ÷ 240 Vac/dc |
| Output type: |
AC/DC |
| Function: |
Changeover relay |
| Actuation type: |
Delayed |
| Delay range (min): |
0 ÷ 1 |
| Sensing distance (mm): |
0 ÷ 25 (adjustable) |
| Hysteresis (%): |
Depends on the switching distance |
| Max. switching frequency: |
Depends on delay |
| Repeatability (%Sn): |
< 1 |
| Max. output current: |
1 A @ 220 Vac |
| Absorption: |
< 20 mA @ relay activated |
| Led indicator: |
Present |
| Shielded: |
Not embeddable |
| Mechanical characteristics: |
M30x1.5 |
| IP rating: |
IP 67 |
| Housing material: |
Polycarbonate/Nickelled brass |
| Connection type: |
Cable 3 m |
| Cable type: |
5x0.35 PVC shielded |
| Weight: |
270 g |
| Operating temperature range: |
-25 ÷ +60 °C |
| Storage temperature range: |
-25 ÷ +70 °C |
| Max. surface temperature: |
+85 °C |
| Limiting device of surface temperature: |
Intervention at 75 ° C non-resettable |
| Explosive atmosphere type: |
Air/Dust mixture |
| Equipment category: |
3D |
| Installation area: |
Zone 22 |
| Protection method: |
Protection by enclosure |
| Marking: |
II 3D Ex tc IIIC T85°C Dc X-25< Ta<60°C |
| Conforming standard: |
EN60079-0, EN60079-31, EN61000-6-2, EN61000-6-4 and EN60947-5-2 |