| Working voltage: |
18 ÷ 50 Vdc / 18 ÷ 240 Vac |
| Detectable rotation range (RPM): |
High range (120 ÷ 3000 adjustable) |
| Swithing distance (Sn): |
4 ÷ 6 mm with metallic plate >= 30x30x1 |
| Delayed alarm activation time: |
9 ÷ 15 sec |
| Response time: |
0.5 ÷ 0.02 sec |
| Autoreset function - B: |
Preset |
| Absorption: |
< 20 mA @ relay ON |
| Output type: |
Changeover relay |
| Max output current: |
1A @ 240 Vac |
| Led indicator: |
Present |
| Housing material: |
Nickelled brass |
| Mechanical characteristics: |
M30X1,5 |
| Cable type: |
5x0.35 PVC Shielded |
| IP rating: |
IP 67 |
| Weight: |
240 g |
| Operating temperature range: |
-25 ÷ +70 °C |
| Storage temperature range: |
-25 ÷ +70 °C |
| Maximum surface temperature: |
+85 °C |
| Limiting device of surface temperature: |
Intervention at 75 ° C non-resettable |
| Explosive atmosphere type: |
Air/Powder mixture |
| Equipment category: |
3D |
| Installation area: |
Zone 22 |
| Protection method: |
Protection by enclosure |
| Marking: |
II 3D Ex tc IIIC T85°C Dc IP67 -25< Ta<70°C |
| Conforming standard: |
EN60079-0 e EN60079-31 |